Castrol Techniclean™ 90 XBC is an aqueous, low alkalinity, industrial process cleaner containing surfactants and

corrosion inhibitors.

The product is formulated without inorganic salts, formaldehyde releasing agents and monoethanolamine (MEA).

Application

Techniclean 90 XBC is designed for inter-operational and final process cleaning operations of ferrous and aluminium

goods, suited for use in a wide range of modern spray, high pressure spray and intensive flood wash equipment.

This cleaner effectively removes residues from parts and components after machining with soluble oils, light duty neat

cutting or forming oils as well as thin corrosion preventive films, lubrication oils, swarf and general dirt.

Techniclean 90 XBC is formulated to be compatible with the Castrol Alusol XBB and Hysol XBB coolant ranges.

When applied in cleaning processes after machining with Alusol and Hysol XBB coolants the used cleaner solution can

be recycled to the previous XBB coolant emulsion system.

Though the product is particularly developed for in-process cleaning, Techniclean 90 XBC is also well suited for

maintenance machine tool cleaning.

Advantages

Leaves a thin temporary corrosion preventive film on the metal surface after drying – minimizes scrap rate which

improves productivity

Effectively minimises excessive foam – reduces costly risk of dangerous cavitations/damage of high-pressure

pumps

Excellent demulsifying properties provide easy skimming and long bath life – can help to reduce maintenance

and disposal cost

Suitable for low temperature cleaning operations - can support sustainability agenda, i.e. helping to reduce

energy cost and to improve CO2 footprint

Versatile; multi-metal compatibility and suitable in hard and soft water – enables possible product consolidation

Possibility of recycling the used cleaning solution into the Alusol and Hysol XBB coolants - can help to reduce

operational cost through lowering waste volume and reducing fresh water consumption

Concentration Control

By titration:

1. Pipette 10 ml bath solution in a 250 ml Erlenmeyer flask and add 50 ml deionised DI-water

2. Add 2 drops of indicator solution nitrazine yellow

3. Titrate with hydrochloric acid (c = 0.1 ml/l) until colour changes from blue to yellow

4. Calculation: Concentration in % = required ml hydrochloric acid * factor 0.63

Additional Information

In case of recyling the used cleaners solution into the coolant system the concentration of the emulsion is maintained by

adding Alusol XBB or Hysol XBB concentrate up to the set level.

For further advice please contact your local Castrol representative.

Storage

To avoid product deterioration always keep the container/drum tightly sealed. Store the product in a cool, dry place away

from direct sunlight. Prevent exposure to frost and avoid water ingress. For optimum product stability, it is preferable to

store the product indoors between 5°C and 45 °C / 41°F and 113°F.